labman Conductivity Meter Specification

  • Product Type
  • labman
  • Power
  • 230V AC, 50Hz
  • Operate Method
  • Manual/Automatic
  • Dimension (L*W*H)
  • 210 205 75mm Millimeter (mm)
  • Classification
  • Laboratory Equipment
  • Usage
  • Measurement of conductivity in liquids
  • Application
  • Laboratory, Educational, Industrial
  • Voltage
  • 230V
  • Material
  • ABS Plastic
  • Capacity
  • 1 cell
  • Color
  • white
  • Weight
  • 2 Kilograms (kg)
  • Calibration
  • Single & Multi-point Calibration
  • Temperature Compensation
  • Manual (using knob)
  • Operating Temperature
  • 10C to 50C
  • Storage Conditions
  • Cool & Dry Place
  • Conductivity Range
  • 0 to 1000 mS/cm
  • Resolution
  • 0.01 S/cm
  • Display Type
  • Digital LCD Display
  • Cell Constant
  • Adjustable (K=1.0 included)
  • Accuracy
  • 1% FSD
  • Electrode Type
  • Platinum conductivity cell
 

labman Conductivity Meter Trade Information

  • Minimum Order Quantity
  • 1 Number
  • Supply Ability
  • 1 Number Per Week
  • Delivery Time
  • 1 Week
 

About labman Conductivity Meter

Digital Conductivity Meter

We are one of the prominent names of the market that engages in presenting Conductivity Meter that is widely recognized for its automatic calibration, auto-ranging conductivity and automatic temperature compensation. These efficient and durable meters are procured from our experienced vendors. Conductivity meters are popular for their adjustable temperature coefficient and cell constant.

Features

Portable
Efficient
Automatic calibration
Details

Wcm Conductivity Meters Includes Measurement Of Conductivity Temperature In Liquids
Automatic Calibration: The Meter Is Capable Of Calibrating Up To 5 Points Using Standard Solution. From Setup Menu, Choose CAL (Calibration) And Press Key To Set Known Conductivity Value, Immerse Conductivity Electrode Into Calibration Solution, Press ENTER Key And Meter Is Automatically Calibrated
Conductivity Auto-Ranging: WCM Series Have Auto-Range Function For Measuring Conductivity. Upon Immersing Conductivity Sensor Into Sample Solution, The Screen Immediately Displays The Value In Appropriate Measurement Range For Accuracy.
Automatic Temperature Compensation: Using The Supplied Temperature Probe, The Temperature Value Is Displayed On The Screen. The Meter Automatically Compensates For Optimum Accuracy Under Variable Temperature Conditions
Adjustable Temperature Coefficient And Cell Constant: Various Ions May Have Different Temperature Coefficients. The Meters Can Set The Temperature Coefficient Between 0 And 3.9 In Degrees Centigrade For Optimum Accuracy, Set Three Cell Constants(O.1,1 And 10) For Measuring Requirements



Precision Measurement for Diverse Applications

With an extensive measurement range and exceptional resolution, the labman Conductivity Meter is tailored for a wide array of liquid conductivity testing needs. Its suitability spans laboratories, educational settings, and industrial processes. The digital LCD display ensures effortless readability, supporting both routine and advanced experiments.


User-Friendly Calibration and Operation

The meter supports single and multi-point calibration for flexible accuracy requirements. Manual temperature compensation allows users to adjust readings as per environmental conditions, using an intuitive knob. The platinum conductivity cell with an adjustable cell constant (K=1.0 included) guarantees reliable and adaptable measurements.


Durable and Compact Design

Engineered with robust ABS plastic and compact dimensions, this instrument fits well in diverse workspaces. Its light weight (just 2 kg) ensures easy portability, while the storage recommendation of a cool, dry place maintains long-term reliability. Operation is seamless on standard 230V AC power.

FAQ's of labman Conductivity Meter:


Q: How do I calibrate the labman Conductivity Meter for precise measurements?

A: Calibration can be performed using either single or multi-point methods. Prepare standard conductivity solutions, dip the platinum electrode, and use the calibration controls to adjust readings accordingly. Calibration ensures optimal accuracy for laboratory and industrial applications.

Q: What is the benefit of manual temperature compensation in this meter?

A: Manual temperature compensation allows users to adjust measurement readings depending on the temperature of the liquid sample, ensuring greater accuracy across varying environmental conditions. Adjustment is performed using the built-in knob on the device.

Q: When should the electrode be cleaned or maintained?

A: It is recommended to clean the platinum conductivity cell after each use, especially if used with samples that can cause deposits. Regular maintenance ensures sustained accuracy and prolongs electrode lifespan.

Q: Where can this conductivity meter be utilized effectively?

A: This instrument is suitable for use in laboratories, educational institutions, and industrial environments where liquid conductivity measurement is required. Its design supports professional use by dealers, exporters, researchers, and laboratory personnel.

Q: What material is used for the meter's body and why is it important?

A: The meter's housing is made from ABS plastic, offering excellent durability, chemical resistance, and light weight. This material ensures both robust protection and ease of handling in various laboratory environments.

Q: How do I store the labman Conductivity Meter when not in use?

A: For optimal performance and longevity, store the meter in a cool, dry place, away from moisture and corrosive substances. Proper storage prevents damage and ensures the device is ready for precise measurements when needed.

Q: What advantages does the digital LCD display provide during measurement?

A: The digital LCD display offers clear, immediate readouts of conductivity values, reducing user error and facilitating easy monitoring of results during experiments or quality control processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Scientific & Laboratory Instrument Category

Digital HotPlate Magnetic Stirrer

Digital HotPlate Magnetic Stirrer

Price 16000 INR / Number

Minimum Order Quantity : 1 Number

Dimension (L*W*H) : 230 x 180 x 120 Millimeter (mm)

Product Type : labman

Application : Pharmaceutical, Chemical, Biological Laboratories

Usage : Mixing and Heating Lab Solutions

PH Transmitter Meter

PH Transmitter Meter

Price 15000 INR / Number

Minimum Order Quantity : 1 Number

Dimension (L*W*H) : 210 205 75 Millimeter (mm)

Product Type : labman

Application : Water treatment, Laboratory, Industrial Processes

Usage : Accurate pH measurement and transmission

DIGITAL Rotational VISCOMETER

DIGITAL Rotational VISCOMETER

Price 103000 INR / Number

Minimum Order Quantity : 1 Number

Dimension (L*W*H) : 400 x 350 x 360 Millimeter (mm)

Product Type : labman

Application : Pharmaceutical, Chemical, Food, Paint, Cosmetics industries

Usage : Measurement of viscosity of liquids

digital Polarimeter

digital Polarimeter

Price 207000 INR / Unit

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : 850 x 470 x 380 Millimeter (mm)

Product Type : table top, portable

Application : Lab, College etc

Usage : Lab, College etc



SWASTIK SYSTEMS & SERVICES
GST : 07AGQPG8382B1Z8
A-12/3, Hardevpuri 100 Feet Road, Shahdara, Delhi - 110093, India
Phone :91-89203-23592
Mr Dayanand Gupta (Managing Director)
Mobile :+919810895623, +919599388861, +918448313665